標(biāo)準(zhǔn)號(hào):IEC 62117-1999
中文標(biāo)準(zhǔn)名稱:核反應(yīng)堆儀表 加壓輕水反應(yīng)堆(PWR) 冷停過(guò)程中堆芯充分冷卻的監(jiān)測(cè)
英文標(biāo)準(zhǔn)名稱:Nuclear reactor instrumentation - Pressurized light water reactors (PWR) - Monitoring adequate cooling within the core during cold shutdown
標(biāo)準(zhǔn)類型:F81
發(fā)布日期:1999/12/31 12:00:00
實(shí)施日期:1999/12/31 12:00:00
中國(guó)標(biāo)準(zhǔn)分類號(hào):F81
國(guó)際標(biāo)準(zhǔn)分類號(hào):27.120.20
適用范圍:This International Standard applies to pressurized water reactors (PWRs) with configurations similar to those shown in figures 1 and 2 and presents requirements for the monitoring of adequate cooling within the core during cold shutdown operations.
Adequate core cooling can be achieved only by providing sufficient coolant flow to the core to remove the heat. During cold shutdown operations, core cooling is provided by forced circulation with the residual heat removal system (RHRS). However, in certain shutdown operations when water level in the reactor pressure vessel (RPV) is reduced for maintenance operations, forced circulation may be interrupted, and the core may become overheated.
It is important that plant operators have reliable information to confirm that the temperature and flow of coolant circulated through the RPV is adequate to remove heat from the core. This information includes a reliable measurement of water level in the RPV outlet piping used for circulating the flow from the core to the RHRS, as well as measurements of temperature and flow of the coolant. An unreliable measurement of water level can result in interruption of coolant flow and overheating of the core, an event that has occurred at several PWRs. Annex A, which describes some of these events, identifies conditions which should be considered in the design of core cooling monitoring instrumentation.
Good international practices to be used when designing new or upgrading existing PWR core cooling monitors are summarized in this standard.
Requirements are given in this standard for instrumentation to monitor core cooling for safe operation of PWRs during cold shutdown operations when the coolant temperature is below 100 ℃ (212 °F). Requirements for core cooling monitoring during conditions beyond a design basis accident (DBA), which could be a specific national requirement or consideration, are not covered in this standard.
The core cooling monitoring instrumentation for cold shutdown functions when the reactor coolant system (RCS) is configured for cold shutdown maintenance or refuelling. The circumstances under which these measurement systems need to function are described in this standard. Descriptions of diverse measuring principles and suitable devices are given together with requirements for the following:
- operational conditions;
- installation;
- operator displays;
- testing, calibration and maintenance;
- equipment qualification;
- documentation.
相關(guān)標(biāo)準(zhǔn)
《2015年版第四部1142》中華人民共和國(guó)藥典 熱原檢查法
《2015年版第四部1148》中華人民共和國(guó)藥典 溶血與凝聚檢查法
《2010年版》中國(guó)獸藥典
《2015年版第四部1147》中華人民共和國(guó)藥典 過(guò)敏反應(yīng)檢查法
《2015年版第四部1141》中華人民共和國(guó)藥典 異常毒性檢查法
《GB/T4547-2007》玻璃容器抗熱震性和熱震耐久性試驗(yàn)方法
《QB/T2297-19976.2.1》微波爐用玻璃托盤(pán)
《GB/T19787-20055.5》包裝材料 聚烯烴熱收縮薄膜
《BB/T0025-20046.1》3026mm塑料防盜瓶蓋
《GB/T19787-20055.12》包裝材料 聚烯烴熱收縮薄膜
百檢網(wǎng)專注于為第三方檢測(cè)機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測(cè)電商服務(wù)平臺(tái),是一個(gè)創(chuàng)新模式的檢驗(yàn)檢測(cè)服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測(cè)服務(wù),簡(jiǎn)化檢測(cè)流程,提升檢測(cè)服務(wù)效率,利用互聯(lián)網(wǎng)+檢測(cè)電商,為客戶提供多樣化選擇,從根本上降低檢測(cè)成本提升時(shí)間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測(cè)平臺(tái)。
百檢能給您帶來(lái)哪些改變?
1、檢測(cè)行業(yè)全覆蓋,滿足不同的檢測(cè);
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測(cè);
3、工程師一對(duì)一服務(wù),讓檢測(cè)更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測(cè)費(fèi)用;
5、自助下單 快遞免費(fèi)上門(mén)取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測(cè)報(bào)告權(quán)威有效、中國(guó)通用;