標準號:BS EN 61558-2-2-2007
中文標準名稱:電力變壓器、供電設備、反應器和類似產品的安全性.控制變壓器和有控制變壓器的供電設備的詳細要求和試驗
英文標準名稱:Safety of power transformers, power supplies, reactors and similar products - Particular requirements and tests for control transformers and power supplies incorporating control transformers
標準類型:K41
發布日期:2007/5/31 12:00:00
實施日期:2007/5/31 12:00:00
中國標準分類號:K41
國際標準分類號:29.180
引用標準:IEC 60076-11
適用范圍:Replacement:This part of IEC 61558 deals with safety aspects of control transformers and power suppliesincorporating control transformers such as electrical, thermal and mechanical safety.This Part 2-2 is applicable to control transformers and power supplies incorporating bothcontrol transformers and electronic circuits. This Part 2-2 is not applicable to externalcircuits and their components intended to be connected to the input terminals, output terminalsor socket-outlets of the transformer and power supplies.This Part 2-2 does not apply to transformers covered by IEC 60076-11.This Part 2-2 applies to stationary or portable, single-phase or poly-phase, air-cooled (naturalor forced), independent or associated control transformers and power suppliesincorporating a control transformer, having a rated supply voltage not exceeding 1 000 Va.c. and rated supply and internal operating frequency not exceeding 500 Hz.The rated thermal output does not exceed:– 25 kVA for single-phase control transformers and power supplies incorporating controltransformers;– 40 kVA for poly-phase control transformers and power supplies incorporating controltransformers.This Part 2-2 is applicable to control transformers and power supplies incorporating controltransformers without limitation of the rated output subject to an agreement between thepurchaser and the manufacturer.This Part 2-2 is applicable to dry-type transformers. The windings may be encapsulated ornon-encapsulated.The no-load output voltage or the rated output voltage does not exceed 1 000 V a.c. or1 415 V ripple-free d.c.For independent control transformers and independent power supplies incorporatingcontrol transformers, the no-load output voltage and / or the rated output voltage is notless than 50 V a.c., or 120 V ripple free d.c.Control transformers covered by this Part 2-2 are used only in applications where double orreinforced insulation between circuits is not required by the installation rules or by the endproduct standard.NOTE 1 Normally, the control transformers and power supplies incorporating control transformers areintended to be used with equipment to provide voltages different from the supply voltage for the functionalrequirements of the equipment. The protection against electric shock may be provided (or completed) by otherfeatures of the equipment, such as the body. Parts of output circuits may be connected to the input circuits or toprotective earth.This Part 2-2 is applicable to control transformers and power supplies incorporating controltransformers associated with specific equipment, to the extent decided upon by the relevantIEC technical committees.NOTE 2 Attention is drawn to the following:– for control transformers and power supplies incorporating control transformers intended to be used invehicles, on board ships and on board aircraft, additional requirements (from other applicable standards,national rules, etc.) may be necessary;– measures to protect the enclosure and the components inside the enclosure against external influences suchas fungus, vermin, termites, solar-radiation, and icing should also be considered ;– the different conditions for transportation, storage, and operation of the control transformers and powersupplies incorporating control transformers should also be considered;– additional requirements in accordance with other appropriate standards and national rules may be applicable tocontrol transformers and power supplies incorporating control transformers intended for use in specialenvironments, such as tropical environments.NOTE 3 Future technological development of control transformers and power supplies incorporating controltransformers may necessitate a need to increase the upper limit of the frequencies, until then this Part 2-2 may beused as a guidance document.
相關標準
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;
相關商品
暫無相關商品