標準號:BS EN 61280-4-4-2006
中文標準名稱:光纖通信子系統基本試驗程序.光纜設施和鏈路.已安裝鏈路的偏振模式色散測量
英文標準名稱:Fibre optic communication subsystem basic test procedures - Cable plants and links - Polarization mode dispersion measurement for installed links
標準類型:M33
發布日期:2006/5/31 12:00:00
實施日期:2006/5/31 12:00:00
中國標準分類號:M33
國際標準分類號:33.180.01
適用范圍:This part of IEC 61280 provides uniform methods of measuring polarization mode dispersion(PMD) of single-mode installed links. An installed link is the optical path between transmitterand receiver, or a portion of that optical path. These measurements may be used to assessthe suitability of a given link for high bit rate applications or to provide insight on therelationships of various related transmission attributes. The principles of this document arealigned with those of the optical fibre and optical fibre cable test method, IEC 60793-1-48 (seeBibliography), which focuses on aspects related to the measurement of factory lengths.Instead, this document focuses on the measurement methods and requirements for measuringlong lengths that might be installed – and that might also include other optical elements, suchas amplifiers, DWDM components, multiplexers, etc.PMD is a statistical parameter. The reproducibility of measurements depends on the particularmethod, but is limited also by the PMD level of the link. Gisin [3]5) derived a theoretical limit tothis reproducibility, by assuming an infinite range of measured wavelengths and idealmeasurement conditions.With the exception of Method D, all methods in this document may be used to measure thePMD in the gain band of links that include pumped optical amplifiers. For these links,amplified spontaneous emission (ASE) noise can generate depolarized spectral energy in theneighbourhood of the measurement wavelength. This will, in general, reduce the accuracy ofthe measurement. For Methods A, B, C, E and F, this effect can be moderated byimplementing an optical or electrical filter at the receive end. However, optical filtering will notremove the ASE right under the signal spectrum. The accuracy will then be limited by a lowerdegree of polarization (DOP), if the spectral width of the filter cannot be sufficiently reducedas with a broadband source. Lower DOP may require the signal to be integrated longer to bemeaningful or the result will become too noisy and interpretation will be erroneous.None of the methods is suitable for measuring the PMD of links with polarization dependentloss (PDL) in excess of 10 dB. Links with PDL values less than 1 dB can be measured withreasonable accuracy. Measurement accuracy may be compromised by the presence of PDL inexcess of 1 dB.
相關標準
《GB/T 11904-1989》水質 鉀和鈉的測定 火焰原子吸收分光光度法 GB/T 11904-1989
《GB 7494-1987》水質 陰離子表面活性劑的測定 亞甲藍分光光度法 GB 7494-1987
《GB 19300-2014》食品安全國家標準 堅果與籽類食品 GB 19300-2014 附錄 B
《GB/T 5750.10-2006》生活飲用水標準檢驗方法 消毒副產物指標 GB/T 5750.10-2006 13.2 離子色譜法-氫氧根系統淋洗液
《GB/T 5750.10-2006》生活飲用水標準檢驗方法 消毒副產物指標 GB/T 5750.10-2006 13.2 離子色譜法-氫氧根系統淋洗液
《GB/T 5750.10-2006》生活飲用水標準檢驗方法 消毒副產物指標 GB/T 5750.10-2006 13.2 離子色譜法-氫氧根系統淋洗液
《GB/T 5750.10-2006》生活飲用水標準檢驗方法 消毒副產物指標 GB/T 5750.10-2006
《GB/T 5750.10-2006》生活飲用水標準檢驗方法消毒副產物指標 GB/T 5750.10-2006 6.1 4-氨基-3-聯氨-5-巰基-1,2,4-三氮雜茂(AHMT)分光光度法
《GB/T5750.4-2006》生活飲用水標準檢驗方法 感官性狀和物理指標 GB/T5750.4-2006 10.1亞甲藍分光光度法
《GB/T 14584-1993》空氣中碘-131的取樣與測定 GB/T 14584-1993
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;