欧洲处破女www人鲁,亚洲无玛,国产bbaaaaa片,三年片在线观看免费播放大全电影国语版

百檢網首頁 我的訂單 400-101-7153

BS ISO/IEC 9314-7-1998 信息處理系統.光纖分布式數據接口(FDDI).物理層協議(PHY-2)

作者:百檢網 時間:2021-07-16

標準號:BS ISO/IEC 9314-7-1998
中文標準名稱:信息處理系統.光纖分布式數據接口(FDDI).物理層協議(PHY-2)
英文標準名稱:Information processing systems - Fibre Distributed Data Interface (FDDI) - Physical layer protocol (PHY-2)
標準類型:L65
發布日期:1998/12/15 12:00:00
實施日期:1998/12/15 12:00:00
中國標準分類號:L65
國際標準分類號:33.180.01;35.110
適用范圍:This part of ISO/IEC 9314 specifies the Physical Layer Protocol (PHY), the upper sublayer of the Physical Layer, for Fibre Distributed Data Interface (FDDI). FDDI provides a high-bandwidth (100 Mbit/s), general-purpose interconnection among information processing systems, subsystems and peripheral equipment, using fibre optics or other transmission media. FDDI can be configured to support a sustained data transfer rate of at least 80 Mbit/s (10 Mbyte/s). FDDI provides connectivity for many nodes distributed over distances of many kilometers in extent. Certain default parameter values for FDDI (e.g. timer settings) are calculated on the basis of up to 1 000 transmission links or up to 200 km total fibre-path length (typically corresponding to 500 nodes and 100 km of dual fibre cable, respectively); however, the FDDI protocols can support much larger networks by increasing these parameter values. As shown in figure 1, FDDI consists of a) Physical Layer (PL), which is divided into two sublayers: 1) A Physical Medium Dependent (PMD), which provides the digital baseband point-to-point communication between nodes in the FDDI network. The PMD provides all services necessary to transport a suitably coded digital bit stream from node to node. The PMD defines and characterizes the fibre-optic drivers and receivers, medium-dependent code requirements, cables, connectors, power budgets, optical bypass provisions, and physical-hardware-related characteristics. It specifies the point of interconnectability for conforming FDDI attachments. The initial PMD standard defines attachment to multi-mode fibre. Alternative PMD sublayer standards are being developed for attachment to other transmission media and for mapping to Synchronous Optical Network (SONET), 2) A Physical Layer Protocol (PHY), which provides connection between the PMD and the Data Link Layer. PHY establishes clock synchronization with the upstream code-bit data stream and decodes this incoming code-bit stream into an equivalent symbol stream for use by the higher layers. PHY provides encoding and decoding between data and control indicator symbols and code bits, medium conditioning and initializing, the synchronization of incoming and outgoing code-bit clocks, and the delineation of octet boundaries as required for the transmission of information to or from higher layers. Information to be transmitted on the medium is encoded by the PHY using a group transmission code. The definition of PHY is contained in this part of ISO/IEC 9314. b) A Data Link Layer (DLL), which is divided into two or more sublayers: 1) An optional Hybrid Ring Control (HRC), which provides multiplexing of packet and circuit switched data on the shared FDDI medium. HRC comprises two internal components, a Hybrid Multiplexer (H-MUX) and an Isochronous MAC (I-MAC). H-MUX maintains a synchronous 125 μs cycle structure and multiplexes the packet and circuit switched data streams, and I-MAC provides access to circuit switched channels, 2) A Media Access Control (MAC), which provides fair and deterministic access to the medium, address recognition, and generation and verification of frame check sequences. Its primary function is the delivery of packet data, including frame generation, repetition, and removal, 3) An optional Logical Link Control (LLC), which provides a common protocol for any required packet data adaptation services between MAC and the Network Layer. LLC is not specified by FDDI, 4) An optional Circuit Switching Multiplexer (CS-MUX), which provides a common protocol for any required circuit data adaptation services between I-MAC and the Network Layer. CS-MUX is not specified by FDDI. c) A Station Management (SMT), which provides the coordination necessary at the node level to manage the processes under way in the various FDDI layers such that a node may work cooperatively on a ring. SMT provides services such as control of configuration management, fault isolatio

相關標準

《GB/T 6995.2-2008》電線電纜識別標志方法 第2部分: 標準顏色 GB/T 6995.2-2008
《GB/T 13849.1-2013》聚烯烴絕緣聚烯烴護套市內通信電纜 第1部分:總則 GB/T 13849.1-2013
《GB/T 13849.1-2013》聚烯烴絕緣聚烯烴護套市內通信電纜 第1部分:總則 GB/T 13849.1-2013
《JB/T 13486-2018》計算機與儀表屏蔽電纜 JB/T 13486-2018
《JB/T 13486-2018》計算機與儀表屏蔽電纜 JB/T 13486-2018
《TB/T 3100.2-2017》鐵路數字信號電纜 第2部分:塑料護套鐵路數字信息電纜 TB/T 3100.2-2017
《TB/T 3100.2-2017》鐵路數字信號電纜 第2部分:塑料護套鐵路數字信息電纜 TB/T 3100.2-2017
《GB/T 8802-2001》熱塑性塑料管材 管件維卡軟化溫度的測定 GB/T 8802-2001 7
《YD/T 1624.1-2015》通信系統用戶外機房 第1部分:固定獨立式機房 YD/T 1624.1-2015 6.3.3.4
《YD/T 1624.2-2015》通信系統用戶外機房 第2部分:一體式固定塔房 YD/T 1624.2-2015 5.3.1
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。

百檢能給您帶來哪些改變?

1、檢測行業全覆蓋,滿足不同的檢測;

2、實驗室全覆蓋,就近分配本地化檢測;

3、工程師一對一服務,讓檢測更精準;

4、免費初檢,初檢不收取檢測費用;

5、自助下單 快遞免費上門取樣;

6、周期短,費用低,服務周到;

7、擁有CMA、CNAS、CAL等權威資質;

8、檢測報告權威有效、中國通用;

客戶案例展示

  • 上海朗波王服飾有限公司
  • 浙江圣達生物藥業股份有限公司
  • 天津市長慶電子科技有限公司
  • 桑德斯微電子器件(南京)有限公司
  • 上海嘉疊貿易有限公司
  • 上海紐特絲紡織品有限公司
  • 無錫露米婭紡織有限公司
  • 東方電氣風電(涼山)有限公司
  • 寧波圖米文具用品有限公司
  • 江蘇力之創特種裝備制造有限公司

相關資訊

暫無相關資訊
百檢網
主站蜘蛛池模板: 武定县| 江达县| 尚志市| 沁阳市| 平凉市| 阿拉善左旗| 阿克苏市| 长阳| 浙江省| 环江| 泸溪县| 巴楚县| 邵武市| 万荣县| 成武县| 寿阳县| 屯留县| 宁晋县| 乌拉特后旗| 吴江市| 崇州市| 商南县| 长顺县| 波密县| 黄大仙区| 乌鲁木齐市| 浙江省| 宁波市| 襄汾县| 石楼县| 繁峙县| 额敏县| 西畴县| 萨嘎县| 冀州市| 泗阳县| 灵寿县| 江城| 和田市| 大姚县| 肥城市|