標(biāo)準(zhǔn)號(hào):BS ISO 15563-1999
中文標(biāo)準(zhǔn)名稱(chēng):乙醇-氯苯輻射劑量測(cè)定系統(tǒng)的實(shí)施規(guī)程
英文標(biāo)準(zhǔn)名稱(chēng):Practice for use of the ethanol-chlorobenzene dosimetry system
標(biāo)準(zhǔn)類(lèi)型:G04
發(fā)布日期:1999/8/15 12:00:00
實(shí)施日期:1999/8/15 12:00:00
中國(guó)標(biāo)準(zhǔn)分類(lèi)號(hào):G04
國(guó)際標(biāo)準(zhǔn)分類(lèi)號(hào):17.240
適用范圍:This practice covers the preparation, handling, testing, and procedure for using the ethanol-chlorobenzene dosimetry system to measure absorbed dose in materials irradiated by photons and electrons in terms of absorbed dose in water. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the ECB system. It is classified as a reference standard dosimeter (see Guide E 1261).This practice describes the titration analysis as a standard readout procedure for the ECB dosimeter. Other applicable readout methods (spectrophotometric, oscillo-metric) are described in Appendixes X1 and X2.This practice applies only to gamma rays, X rays, and high-energy electrons. This practice applies provided the following are satis-fied: The absorbed dose range shall be from 10 Gy to 2 MGy (1).The absorbed dose rate does not exceed 10 Gy s (2).For radionuclide gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 4 MeV (see ICRU Reports 34 and 35). Note 1—The lower limits of electromagnetic radiation energy given are appropriate for a cylindrical dosimeter ampoule of 12-mra diameter. Corrections for dose gradients across an ampoule of that diameter or less are not required. The ECB system may be used at energies of incident electrons lower than 8 MeV by employing thinner (in the beam direction) dosimeter containers (see ICRU Report 35).The irradiation temperature of the dosimeter should be within the range from -40℃ to 80℃.This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
相關(guān)標(biāo)準(zhǔn)
《GB 31223-2014》氣象探測(cè)環(huán)境保護(hù)規(guī)范 天氣雷達(dá)站 GB 31223-2014 5.4,6.2
《HJ/T 10.2-1996》輻射環(huán)境保護(hù)管理導(dǎo)則-電磁輻射監(jiān)測(cè)儀器和方法 HJ/T 10.2-1996 1,2
《HJ/T 10.2-1996》輻射環(huán)境保護(hù)管理導(dǎo)則-電磁輻射監(jiān)測(cè)儀器和方法 HJ/T 10.2-1996 1,2
《YD/T 3026-2016》通信基站電磁輻射管理技術(shù)要求 YD/T 3026-2016 9.10
《HJ/T 10.2-1996》輻射環(huán)境保護(hù)管理導(dǎo)則-電磁輻射監(jiān)測(cè)儀器和方法 HJ/T 10.2-1996 1,2
《YD/T 3026-2016》通信基站電磁輻射管理技術(shù)要求 YD/T 3026-2016 9.10
《HJ/T 10.2-1996》輻射環(huán)境保護(hù)管理導(dǎo)則-電磁輻射監(jiān)測(cè)儀器和方法 HJ/T 10.2-1996 1,2
《YD/T 3026-2016》通信基站電磁輻射管理技術(shù)要求 YD/T 3026-2016 9.10
《GBZ115-2002》X射線衍射儀和熒光分析儀衛(wèi)生防護(hù)標(biāo)準(zhǔn) GBZ115-2002
《GBZ117-2015》工業(yè)X射線探傷放射防護(hù)要求 GBZ117-2015
百檢網(wǎng)專(zhuān)注于為第三方檢測(cè)機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測(cè)電商服務(wù)平臺(tái),是一個(gè)創(chuàng)新模式的檢驗(yàn)檢測(cè)服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測(cè)服務(wù),簡(jiǎn)化檢測(cè)流程,提升檢測(cè)服務(wù)效率,利用互聯(lián)網(wǎng)+檢測(cè)電商,為客戶提供多樣化選擇,從根本上降低檢測(cè)成本提升時(shí)間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測(cè)平臺(tái)。
百檢能給您帶來(lái)哪些改變?
1、檢測(cè)行業(yè)全覆蓋,滿足不同的檢測(cè);
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測(cè);
3、工程師一對(duì)一服務(wù),讓檢測(cè)更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測(cè)費(fèi)用;
5、自助下單 快遞免費(fèi)上門(mén)取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測(cè)報(bào)告權(quán)威有效、中國(guó)通用;